DHD Controller SpeCifiCationS
DHD™ CONTROLLER
he Video Xtreme portfolios VX-2000d and VX-6000d include Runcos
DHD™ controller/processor. The DHD is engineered with advanced VivixII®
digital video processing to produce stunning video imagery, even elevating
standard NTSC material to near high definition levels. Superb scaling capabilities
output all signals at the 1080p native display resolution of the projectors.
Runcos DHD provides for a pure digital signal path from input to output and resides outboard of the projector chassis. This simplifies installation
by placing the DHD and its associated input connections in the equipment rack. Only one digital signal cable is then required to the projector.
These projection systems can also take full advantage of Runcos exclusive LiveLink® digital cable solution to preserve HD signal quality and
bandwidth over much longer runs than conventional digital signal cables.
Aspect Ratios:
4:3, 16:9 Anamorphic, Letterbox,
VirtualWide™,Cinema, 2.35 Cinema
Video Standards: NTSC, PAL, ATSC
Output Resolution:
1080P
Outputs:
(1) HD - R (Pr), G (Y), B (Pb), H, V;
(1) HDMI w/HDCP
Inputs:
(1) Composite; (2) S-Video; (1) Component;
(2) HD - R (Pr), G (Y), B (Pb), H, V;
(2) HDMI w/HDCP
Communication
Control Ports:
RS-232 (via DB9 connector),
(1) RJ-11 output (for display only),
IR (with discreet commands),
Front panel controls
Screen Trigger/
Masking Outputs:
(3) +12 VDC, each rated at 750 mA and
thermal fuse-protected
Bandwidth:
150 Mega Samples/Second (MSPS)
Power Requirements:
100 240V AC (auto sensing)
50/60 Hz, 160W
Operating
Environments:
41°– 95° F, (5° – 35° C),
0% – 90% Humidity (non-condensing)
Dimensions:
(w/out feet)
Width: 17 1/2 in. (444.50 mm),
Depth: 11 3/16 in. (284.10 mm),
Height: 3 3/4 in. (95.25 mm),
Weight: 13 lbs. (5.9 kg)
Included Accessories: Rack mounting brackets
Limited Warranty:
(2) Two years parts and labor from the date
of delivery to the end user