Runco VX-1000d Specifications Page 75

  • Download
  • Add to my manuals
  • Print
  • Page
    / 90
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 74
Runco VX-2000d Owner’s Operating Manual 63
PRE
L
IMINAR
Y
5.1
Lamp Replacement
The lamp should be replaced when it reaches the end of its life (typically 2000 hours), or
sooner if a noticeable degradation in brightness occurs. Contact your Runco dealer to
obtain a replacement lamp.
1. Turn off the projector and unplug the power cord. Allow the projector to cool down for
approximately 45 minutes prior to removing the lamp assembly for replacement.
2. Using a Phillips screwdriver, loosen the two Lamp
Cover screws on the side of the projector and
remove the cover.
3. Remove the three Phillips round-head lamp
assembly mounting screws. These are identified by
arrows pointing to them on the lamp housing.
4. Grasp the lamp assembly handle and pull gently, removing the lamp module from the
projector housing.
5. Install the new lamp module. Secure it in place with the three screws that you
removed in Step 3.
6. Replace the lamp cover and re-tighten the two Lamp Cover screws.
7. Re-connect the AC power cord to the projector.
8. Reset the Lamp Hour counter by doing either of the following:
On the projector rear-panel keypad (see Figure 2-6), press and hold the
ENTER, DOWN and RIGHT buttons simultaneously. Then, press the ON button.
On the DHD Controller front panel (see Figure 2-3), while pressing and holding
the ENTER button, press the POWER ( ) button.
When you do, “LAMP 0000H” appears on-screen to confirm the counter reset.
5. Maintenance and Troubleshooting
Always reset the Lamp Hour counter when you replace the lamp.
Do this only if you have just installed a new lamp. This will ensure
that number of hours logged on the lamp is accurate.
REMOVE
THESE SCREWS
Note