Runco Q-650i Series Owner's Manual Page 18

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 17
3433
Universal Remote Control, Inc.
EMITT - Setting IR Emitter Outputs
The MRF-250 and MRF-300 Base Stations enable you to route or
steer the IR commands from any Device to any or all of the IR
Line Outputs. This allows you to control identical devices using
the exact same IR commands (such as an array of television sets
in a media room or a stack of identical satellite receivers installed
in a central location with one satellite receiver dedicated to each
room with a television). Each button push (or macro step) is rout-
ed to the specific IR Line Output you’ve assigned to a device. In
the factory set default settings, the Omega is set to route IR com-
mands from any device to ALL IR Line Outputs simultaneously. To
change the Omega default settings follow these steps:
From the RF Settings Menu, select EMITT.
Decide whether you are changing the Emitter settings for all devices
or just one of the devices of the Omega.
Select ALL to change the Emitter settings to
ALL devices in the Omega. Then, go to Step
4.
Select DEVIC to change the Emitter settings
to just one of the devices in the Omega.
Then, go to Step 3.
The Omega
1
2
Select the new setting by pressing the desired button, then press SAVE
to save your new setting and return to the RF settings menu.
4
Change ID#
using UP and
DOWN buttons
Displays the
current ID#
Save the new setting
Exit this Menu with-
out changing the
IR/RF settings
ID # - Setting Base Station Address
When you are installing a system within 100 feet of another equipment
location in the same home OR near a home, condo, yacht or motor
home that might potentially have an RF remote control of any kind, it is
recommended that you use an addressable base station and set the
address as described here.
You can operate up to 15 different equipment locations, each with an
MRF-250 or MRF-300 assigned a unique Receiver ID#. You program
each or all of your Omega devices to the appropriate equipment loca-
tion by assigning the corresponding ID# in the RF Settings Menus.
From the RF Settings Menu, select ID#.
Decide whether you are changing the ID# for all devices or just one
of the devices of the Omega.
Select ALL to change the ID# for ALL devices
in the Omega. Then, go to Step 4.
Select DEVIC to change the ID# for just one
of the devices in the Omega. Then, go to Step
3.
The display changes to a list of the names of your devices. If you have
two pages of devices, pressing either of the page buttons will display
the other page. Select the device you would like to change the ID#,
then go to Step 4.
1
2
3
Select a device
Page Button
displays the
other page
of devices.
OCE-0031B Rev05_130x220 2007.5.14 9:55 AM 페이지33
Page view 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 31 32

Comments to this Manuals

No comments