Operation
82 Q-750d Ultra Series Installation/Operation Manual
PRE
L
IMINAR
Y
Front Panel Brightness: Select Front Panel Brightness from the Service menu to adjust
the brightness of the front-panel LED and LCD status indicators.
Logo LED: Select Logo LED from the Front Panel Brightness menu to adjust the
brightness of the large, illuminated logo on the left side of the display. The range is from
0 (off) to 31.
Standby LED: Select Standby LED from the Front Panel Brightness menu to change
the behavior of the front-panel STANDBY indicator LED. When set to ON, the LED
lights amber when the system is in standby mode; otherwise, it is off. When set to OFF,
the LED is always off.
•LCD: Select LCD from the Front Panel Brightness menu to adjust the brightness of the
front-panel LCD. The range is from 0 (off) to 4.
Auto Power Off: Select Auto Power Off from the Service menu to have the Q-750d Ultra
turn itself off after a period of inactivity (no source signal present).
•Enable: By default, Auto Power Off is disabled. To enable it, select Enable from the
Auto Power Off sub-menu and set it to On.
•Hours: The default time-out period is eight (8) hours; the range is from 1 to 24 hours.
During a firmware upgrade, this LED lights at full brightness
regardless of the Logo LED setting.
During a firmware upgrade, this LED lights at full brightness
regardless of the Standby LED setting.
Logo LED
LCD
Standby LED
Note
Note